Dielectric Thickness and Breakdown Voltage in Aluminum PCBs

One thin layer insulates the circuit and carries the heat, so every micron added for voltage is paid for in temperature.

Published by ChengYue on . 5-minute read.

The breakdown voltage of an aluminum PCB is set by the dielectric between the copper circuit and the metal base, and so is most of its thermal resistance. Making that layer 50 % thicker adds 50 % to the thermal resistance and, at best, 50 % to the breakdown voltage.

What breakdown voltage does an aluminum PCB need?

An aluminum PCB needs a laminate breakdown rating well above the hi-pot level of the end product, and that level comes from the product's safety standard and working voltage.

A long-standing rule of thumb for basic insulation is a test at 2 × working voltage + 1,000 V AC. For 230 V mains that gives about 1.5 kV AC. Reinforced mains insulation is commonly tested near 3 kV AC. For an 800 V EV traction or charging circuit the same rule gives 2.6 kV AC, before any margin the system standard adds. The standard in your product approval sets the real number.

Laminate breakdown is measured on clean coupons, without the holes, routed edges and handling damage of a finished board, hence the margin.

Does a thicker dielectric mean worse heat transfer?

Yes: thermal resistance through the dielectric is proportional to its thickness, while breakdown voltage rises by at most the same proportion and usually less.

R″ = t / k

Generic example: a 2 W/m·K dielectric under a 5 × 5 mm pad (0.25 cm²) dissipating 3 W, one-dimensional; copper spreading makes real boards a little cooler.

Same 2 W/m·K dielectric at two thicknesses (generic worked example)
ThicknessR″ (°C·cm²/W)R under pad (K/W)ΔT at 3 W (K)Breakdown, relative
100 µm0.502.061.0×
150 µm0.753.09up to ~1.5×

100 µm: 0.0001 m / 2 W/m·K = 5.0 × 10⁻⁵ m²·K/W = 0.50 °C·cm²/W
0.50 / 0.25 cm² = 2.0 K/W → 3 W × 2.0 K/W = 6 K

To gain voltage without gaining temperature, raise the grade with the thickness: 150 µm at 3 W/m·K is 0.50 °C·cm²/W, the same as 100 µm at 2 W/m·K (see aluminum PCB thermal conductivity).

Dielectric strength in kV/mm falls as thickness grows, partly because a thicker layer holds more voids, so doubling thickness rarely doubles breakdown voltage.

What is the difference between breakdown voltage and hi-pot test voltage?

Breakdown voltage is where the dielectric punctures when the voltage is ramped up; hi-pot (dielectric withstand) voltage is a lower level held for a fixed time to show the insulation survives. Breakdown destroys the sample; withstand can be run on every board.

Working voltage
The highest voltage the insulation sees continuously in service
Hi-pot / withstand voltage
A set voltage for a set time, typically 60 s in type tests, or 1–2 s at a raised level in production; pass if leakage stays under a limit and nothing flashes over
Breakdown voltage
The voltage at puncture under a defined ramp, electrode and environment

Laminate breakdown is measured with methods in the IPC-TM-650 2.5.6 family for printed board material, or general insulating-material methods such as IEC 60243-1 and ASTM D149. Electrode shape, ramp rate and conditioning differ, so two figures compare only when the method matches (see reading an IMS datasheet).

Should the hi-pot test be AC or DC?

Use the type your end-product standard specifies and write it down, because AC and DC figures are not interchangeable. Many safety standards accept a DC test at the AC peak, √2 × RMS, so 3 kV AC RMS corresponds to about 4.24 kV DC.

AC also drives capacitive current through the large copper-to-base area of an IMS board. A 100 µm dielectric with a relative permittivity of about 5 under 50 cm² of copper is about 2.2 nF:

C = ε0 · εr · A / t = 8.85 × 10−12 × 5 × 0.005 / 0.0001 ≈ 2.2 nF
I = 2π · f · C · V = 2π × 50 × 2.2 × 10−9 × 3,000 ≈ 2.1 mA

That 2 mA flows through sound insulation, so a tester set to a 1 mA AC limit fails a good board. DC shows the true leakage once the charging current settles, and is common for 100 % production testing of IMS boards.

Why do some IMS laminates carry a 6 kV breakdown rating?

A 6 kV breakdown rating leaves 1.5–2× headroom over hi-pot levels of 3–4 kV on the same AC or DC basis, for circuits that put mains or high-voltage DC directly on the metal-core board. Offline LED drivers, on-board chargers, solar inverters and motor drives are typical.

The headroom covers losses from drilling, routing and ageing. Our high-voltage grades are rated 6 kV AC breakdown on a 100 µm dielectric; thermal figures are on each grade's datasheet, and grade, base and copper can be matched in the laminate selector.

What should the drawing or PO say about the dielectric test?

A drawing note for the dielectric test needs the voltage, AC or DC, duration, leakage limit, test points and sampling; "Hi-pot 3 kV" alone leaves most of that open.

  • Laminate: conductivity grade and minimum breakdown voltage with test method.
  • Test voltage and type: e.g. 3,000 V AC RMS 50 Hz, or 4,240 V DC.
  • Duration and ramp: e.g. ramp to level in 5 s, hold 60 s.
  • Pass criteria: leakage limit in mA, set above the board's capacitive current for an AC test, and no flashover or breakdown.
  • Test points: all copper nets shorted together, to the metal base.
  • Sampling: 100 % of finished boards, or a stated sample per lot.

For the 50 cm² board above: "Hi-pot all copper to aluminum base, 3.0 kV AC RMS 50 Hz, ramp 5 s, hold 60 s, leakage ≤ 5 mA, no breakdown or flashover, 100 % of boards." Laminate sheets are hi-pot tested after pressing (see the factory page), but only the finished-board test covers the edges and holes your design added.

Next step

Pick the grade, base, copper weight and sheet size in the selector and send it as a sample request. Or put a question about this note to us directly.

Open the laminate selector

More from the blog