High CTI FR-4 (CTI 600) and What It Changes on a PCB Layout
CTI rates how a laminate surface resists tracking. It picks the creepage column you read from, and nothing else.
High CTI FR-4 is FR-4 whose surface withstands tracking at 600 V or more in the comparative tracking index test, which puts it in material group I of IEC 60664-1. Standard FR-4 commonly rates 175–250 V, group IIIa. The group decides which creepage column applies to the board, and that is where the layout gain comes from.
- Group I
- CTI ≥ 600 V
- Group II
- 400 V ≤ CTI < 600 V
- Group IIIa
- 175 V ≤ CTI < 400 V
- Group IIIb
- 100 V ≤ CTI < 175 V
CTI is measured under IEC 60112 (ASTM D3638 in the US; UL 746A reports it as a performance level category, PLC 0 meaning ≥ 600 V). Ammonium chloride solution drips every 30 seconds between two platinum electrodes 4 mm apart, and CTI is the highest voltage at which the surface survives 50 drops without forming a conductive track. The test stops at 600 V, so "CTI ≥ 600" is the top of the scale.
What CTI changes on the layout
At 400 V RMS working voltage and pollution degree 2, basic insulation needs 2.0 mm of creepage on a group I material and 4.0 mm on group III under the general creepage table of IEC 60664-1. Across that table, group III needs roughly twice the group I distance.
| Insulation | Group I, mm | Group II, mm | Group III, mm |
|---|---|---|---|
| Basic | 2.0 | 2.8 | 4.0 |
| Reinforced (2 × basic) | 4.0 | 5.6 | 8.0 |
A 400 V primary-to-SELV gap with reinforced insulation drops from 8.0 mm to 4.0 mm when the board moves from group III to group I. Around a gate-driver isolation barrier or a mains connector, that can remove a routed slot or shrink the board.
Two limits apply. IEC 60664-1 also has separate columns for printed wiring material, which do not split groups I to IIIa; if your end-product standard (IEC 62368-1, IEC 60335-1, IEC 61010-1 and others each have their own rules) lets you use them, much of the CTI gain at pollution degree 2 goes away, and it returns at pollution degree 3. And the gain needs a CTI figure on the laminate datasheet: where the material group is not known, IEC 62368-1 has you assume group IIIb.
What it doesn't change
CTI is a surface rating, so through-thickness and through-air properties stay where they were.
- Breakdown voltage. Dielectric strength through the laminate is tested separately (IEC 60243, or IPC-TM-650 2.5.6 for PCB materials) and depends on resin, glass and thickness. A CTI 600 core and a standard core of the same thickness can break down at similar kV; the thickness side is in dielectric thickness and breakdown voltage.
- Clearance. The shortest path through air depends on impulse withstand voltage, altitude and pollution degree, and the board material plays no part. Creepage can never be shorter than the required clearance, so at high impulse voltages clearance may set the gap and the CTI gain shrinks.
- Tg. Glass transition temperature and CTI are independent. A high-Tg laminate can have a low CTI, and a CTI 600 laminate is not automatically suited to repeated lead-free reflow. Check both lines on the datasheet.
Where the other FR-4 and CEM-3 grades fit
Alongside the metal-core laminates, we make three rigid grades for boards where a metal base is the wrong choice.
- FR-4, CTI ≥ 600 V
- Group I, for creepage-limited high-voltage boards
- Halogen-free FR-4
- Tg ≥ 150 °C
- Thermally conductive CEM-3
- 2 W/m·K
Halogen-free FR-4 is specified when a customer or market limits halogens; the usual definition (IEC 61249-2-21) is chlorine ≤ 900 ppm, bromine ≤ 900 ppm and ≤ 1,500 ppm combined. Its Tg ≥ 150 °C sits above standard FR-4, usually around 130–140 °C. Its CTI is a separate line on its datasheet.
Thermally conductive CEM-3 suits a board that needs some heat spreading but not a metal core: one with through-hole parts, components on both sides, or a voltage that rules out a thin dielectric over grounded aluminium. As a generic example, heat crossing 1.6 mm of laminate sees:
1.6 mm at 0.3 W/m·K (typical standard FR-4): R = t / k = 0.0016 / 0.3 = 0.0053 m²·K/W = 53 °C·cm²/W
1.6 mm at 2.0 W/m·K: R = 0.0016 / 2.0 = 0.0008 m²·K/W = 8 °C·cm²/W
100 µm IMS dielectric at 2.0 W/m·K: R = 0.0001 / 2.0 = 0.00005 m²·K/W = 0.5 °C·cm²/W
The 2 W/m·K CEM-3 cuts through-board resistance by more than six times against standard FR-4, and a metal-core laminate is lower again by a factor of 16 because its dielectric is 16 times thinner. If the heat is a few watts on a small pad, start from how an IMS laminate moves heat; if the limit is creepage or double-sided assembly, start from these grades in the selector.
Next step
Pick the grade, base, copper weight and sheet size in the selector and send it as a sample request. Or put a question about this note to us directly.
Open the laminate selector